| Queensland Smoke Alarm Compliance Checklist – 2025 | ||
|---|---|---|
| 1 | Smoke Alarm Type | * Photoelectric alarms only (no ionisation) |
| * Alarms less than 10 years old | ||
| * 10 year sealed lithium battery or 240V hardwired | ||
| 2 | Location Requirements | * One alarm in every bedroom |
| * One alarm in hallways connecting bedrooms | ||
| * At least one alarm on every storey | ||
| 3 | Interconnection | * All alarms interconnected (wireless or hardwired) |
| * All alarms trigger together when one activates | ||
| 4 | Installation Rules | * Ceiling mounted (preferred) |
| * If wall-mounted: 300–500mm below ceiling | ||
| * Minimum 300mm from corners | ||
| * Minimum 400mm from fans or aircon vents | ||
| 5 | Testing & Operation | * All alarms tested and sounding correctly |
| * Audible from all bedrooms | ||
| * No dust, insects, or contamination | ||
| 6 | Selling / Renting Compliance | * Home meets all QLD 2027 requirements |
| * Compliance documented pre settlement / lease | ||
| * Installer compliance form provided | ||
Queensland Fire Dept
The most trusted government source. Clear rules, diagrams, and videos on where alarms must go and what type is required.
Watch Smoke Alarms maintains this website, as a public- interest initiative. The content is provided to educate, connect and protect. At Watch we believe in building meaningful partnerships with businesses, organizations and charities that share our vision and values of leadership, compassion, and integrity. Together we have opportunities to make a real difference together, so that lives are saved.